Table 1. Light path diagnostics panel LEDs. Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action step is preceded by " trained technician only ," that step must be performed only by a trained technician.
Check the IMM2 system event log and the system-error log for information about the error. Save the log if necessary and clear the log afterwards. System-error LED An error has occurred. Check the light path diagnostics LEDs and follow the instructions. The system might detect a power supply error. Make sure that the power supplies are seated correctly and plugged in a good AC outlet.
Remove one of the power supplies to isolate the failed power supply. Make sure that both power supplies installed in the server are of the same AC input voltage. Replace the failed power supply. If the CONFIG LED and the CPU LED are lit, complete the following steps to correct the problem: Check the microprocessors that were just installed to make sure that they are compatible with each other see Replacing a microprocessor and heat sink for additional information about microprocessor requirements.
The following table shows the internal storage expansion options that are available for x M4 server. The following table lists the RAID controllers and additional options used for internal disk storage of x M4 server.
The following table lists currently available drive options for the internal disk storage of the x M4 server. The server supports the internal tape drive options listed in the following table. This drive also supports the following media and speeds for writing:.
The server supports up to six PCIe slots with different riser cards installed into two riser sockets on the system planar one riser socket supports installation of one riser card. Riser 1 supplies slots 1, 2, and 3. Riser 2 supplies slots 4, 5, and 6.
Standard models have Riser card 1 installed with three PCIe 3. To enable slots 4 - 6, install a second processor and a second riser card. Figure 6. Slot dimensions. The specific slots that are available depend on the riser cards installed in Riser socket 1 and Riser socket 2, as shown in the following table. Standard models have 69Y installed in Riser socket 1. Tip : All slots support full-height adapters. Slots 1, 4, and 5 support full-length adapters, whereas slots 2, 3, and 6 when present support half-length adapters.
The Thermal Solution Kit is not needed if two processors are installed, since the second processor includes this fan. The x M4 supports four integrated Gigabit Ethernet ports. Optionally, two 10 Gb Ethernet ports can be added by installing one of the dual-port 10 Gb Ethernet mezzanine cards listed in the following table. These cards use a dedicated connector on the motherboard and do not consume a PCI expansion slot. The following table lists additional network adapters that are currently available for the x M4.
Maximum quantity is achieved with two processors installed. With one processor, the maximum quantity is half of the listed value this does not apply to mezzanine cards. The following table lists storage HBAs available for the x M4 server. The maximum quantity listed is for configurations with two processors installed. If one processor is installed, the maximum quantity supported is half of the listed value. The server cannot be shipped with these adapters installed.
The server supports GPUs provided the appropriate riser card is installed one or two riser cards depending on the number of GPUs. For all other GPUs, riser card 90Y is used. The server provides up to W of external power to each GPU.
The following table lists the supported GPUs. The server supports up to two redundant power supplies. Standard models come with one or two power supplies model dependent. The following table lists the power supplies. The key is installed in a USB socket inside the server. The following table lists the virtualization options. If an environmental condition exceeds a threshold or if a system component fails, the IMM2 lights LEDs to help you diagnose the problem, records the error in the event log, and alerts you to the problem.
Optionally, the IMM2 also provides a virtual presence capability for remote server management capabilities. The optional Integrated Management Module Advanced Upgrade is required to enable the remote presence and blue-screen capture features.
The remote presence feature provides the following functions:. The blue-screen capture feature captures the video display contents before the IMM restarts the server when the IMM detects an operating-system hang condition. A system administrator can use the blue-screen capture to assist in determining the cause of the hang condition.
The following table lists the remote management option. All standard models ship with a pop-out light path diagnostics panel on the front of the server See Figure 2.
Configure-to-order CTO customers may elect to deselect this feature and instead have a basic light path diagnostics panel on the front of the server.
The following table shows the two light path diagnostics features. The System x M4 has a three-year warranty with 24x7 standard call center support and 9x5 Next Business Day onsite coverage.
Also available are Lenovo Services warranty maintenance upgrades and post-warranty maintenance agreements, with a well-defined scope of services, including service hours, response time, term of service, and service agreement terms and conditions. Lenovo warranty service upgrade offerings are country-specific. Not all warranty service upgrades are available in every country.
Offerings vary and are available in select countries. In the unlikely event of a hard drive failure, you retain possession of your hard drive while Lenovo replaces the failed drive part.
Your data stays safely on your premises, in your hands. The Hard Drive Retention service can be purchased in convenient bundles with our warranty upgrades and extensions. Keeping microcode current helps prevent hardware failures and security exposure. There are two levels of service: analysis of the installed base and analysis and update where required. Offerings vary by country and can be bundled with other warranty upgrades and extensions. RTS provides comprehensive technical call center support for covered servers, storage, operating systems, and applications.
Providing a single source for support of hardware and software issues, RTS can reduce problem resolution time, decreasing the cost to address technical problems and increasing uptime. The x M4 can also be attached to supported external storage systems, such as the Lenovo Storage S see the External disk storage systems section. The controllers support connectivity to the external expansion enclosures listed in the following table.
Up to nine expansion enclosures can be daisy-chained per one controller external port. For better performance, distribute expansion enclosures evenly across both controller ports. The following table lists the external storage systems that are offered by Lenovo that can be used in x M4 solutions. The following table lists the external backup options that are offered by Lenovo that can be used in x M4 solutions.
Flash of [arg1] from [arg2] succeeded for user [arg3]. Flash of [arg1] from [arg2] failed for user [arg3].
Platform Watchdog Timer expired for [arg1]. Management Controller Test Alert Generated by [arg1]. Please attempt to flash the [arg3] firmware.
Domain name set to [arg1]. Domain Source changed to [arg1] by user [arg2]. DDNS setting changed to [arg1] by user [arg2]. The domain name is [arg1]. DDNS registration successful. IPv6 enabled by user [arg1]. IPv6 disabled by user [arg1]. IPv6 static IP configuration enabled by user [arg1]. IPv6 stateless auto-configuration enabled by user [arg1]. IPv6 static IP configuration disabled by user [arg1]. IPv6 stateless auto-configuration disabled by user [arg1]. IPv6 static address of network interface modified from [arg1] to [arg2] by user [arg3].
Planar 12V bc01xxxx : Numeric sensor [NumericSensorElementName] going high upper non-recoverable has asserted. Planar Fault a01xxxx : Sensor [SensorElementName] has transitioned to critical from a less severe state. Sys Board Fault xxxx : Sensor [SensorElementName] has transitioned to non-recoverable from a less severe state.
Firmware Error fbxxxx : The connector [PhysicalConnectorElementName] has encountered a configuration error. Watchdog fb01xxxx : [ManagedElementName] detected as absent. Search titles only. Search Advanced search…. New posts. Search forums. Log in. Sign up. Computer problem? Tech Support Guy is completely free -- paid for by advertisers and donations. Click here to join today! JavaScript is disabled. For a better experience, please enable JavaScript in your browser before proceeding.
NMI Button for x server.
0コメント